![Texas Instruments AM1802 Скачать руководство пользователя страница 102](http://html.mh-extra.com/html/texas-instruments/am1802/am1802_reference-manual_1094556102.webp)
PLLC Registers
7.3.35 PLLC1 SYSCLK Status Register (SYSTAT)
The PLLC1 SYSCLK status register (SYSTAT) indicates the PLL1_SYSCLKn on/off status. The actual
default is determined by the actual clock on/off status, which depends on the DnEN bit in PLLC1 PLLDIVn.
SYSTAT is shown in
and described in
Figure 7-36. PLLC1 SYSCLK Status Register (SYSTAT)
31
8
Reserved
R-0
7
3
2
1
0
Reserved
SYS3ON
SYS2ON
SYS1ON
R-0
R-0
R-0
R-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 7-38. PLLC1 SYSCLK Status Register (SYSTAT) Field Descriptions
Bit
Field
Value
Description
31-3
Reserved
0
Reserved
2
SYS3ON
PLL1_SYSCLK3 on status.
0
Off
1
On
1
SYS2ON
PLL1_SYSCLK2 on status.
0
Off
1
On
0
SYS1ON
PLL1_SYSCLK1 on status.
0
Off
1
On
102
Phase-Locked Loop Controller (PLLC)
SPRUGX5A
–
May 2011
Copyright
©
2011, Texas Instruments Incorporated