Termostroj
Croatia
APPENDIX - 7
Termo-Blok-m
4. Control panel Termo-Blok-m
Automatic consists of the following elements:
1. INDICATOR OF TEMPERATURE /PRESSURE IN BOILER
2. TEMPERATURE REGULATOR - capillary thermostat
3. SWITCH FOR THE 2
ND
AND 3
RD
OPERATION STAGE
4. LIMITING THERMOSTATE WITH MANUAL DEACTIVATION (switches off on ca 115
o
C)
5. INDICATOR OF AIR APPEARANCE IN THE BOILER - air-indicator
6. SWITCH FOR AUTOMATICS’ FEEDING WITH 220V + 1
ST
OPERATION STAGE
7. GLAS FUSE 2,5A PROTECTING THE PUMP AND SWITCHES
8. INDICATION OF HEATER OPERATION
9. INDICATES LOW VOLTAGE PROTECTION - UNDER 180V