TMS-UT-0114-T01-1
Red dot in lower right corner of display is showing - boiler is off on control panel but main power
(RCCB switch) is in ON position
Display is showing real temperature in boiler - red dot is illuminate
Display is showing real temperature in boiler, red dot is blinking - in cascade mode boiler wait cascade
signal for start from previous boiler
Display show settings parameter during programming - without red dot
Clarification of LED display layout
5.6.2. Central heating functions
Display of wanted boiler temperature
By pressing the key (6) user can see the wanted boiler
temperature.(calculated from the selected correction curve)
Display shows wanted bolier temperature. The value is displayed for 5 s,
after which display returns to indication of the actual temperature of water in
the boiler.
Correction curve selection
By pressing the key (6) user can enter curve selection menu.
By pressing the key, curve number changes in increment of 0,1 within the
set, according to the diagram on the front panel. If the key is depressed for
more than 5s, value on the display will be memorized and becomes active.
Radiator heating: Adjustment range 1..3, factory default 1,5
Underfloor heating: Adjustment range 0,2..0,9 factory default 0,6
Manual setting of wanted boiler temperature
By pressing the key (6) user can set wanted boiler temperature and
override curve correction.
By pressing the key up or down user can select fixed temperature in the
boiler. If the key is depressed for more than 5s, value on the display will be
memorized and becomes active.
When boiler is in fixed temperature mode, the LED display blinks while
displaying current boiler temperature and all correction curves are
ignored. To return to the correction curve mode, the boiler must be
switched off and back on using ON/OFF switch.
User can further adjust
temperature by pressing key(6) again if necessary.
Radiator heating: Adjustment range 27°C-80°C, factory default 60°C
Underfloor heating: Adjustment range 20°C-45°C, factory default 40°C
Page 30
Содержание TERMO-Blok
Страница 2: ...TMS UT 0114 T03 1 INSTRUCTIONS FOR USE We reserve the right of alternations ...
Страница 25: ...TMS UT 0114 T01 1 INSTRUCTIONS FOR INSTALLATION We reserve the right of alternations ...
Страница 66: ...TMS UT 0114 T01 1 Page 39 ...
Страница 76: ...Termostroj Croatia APPENDIX 3 Termo Blok PTV m 2 Electric sketch Termo Blok PTV m 3 Connection plate Page 49 ...
Страница 83: ...Termostroj Croatia APPENDIX 5 Termo Blok e 2 Electric sketch Termo Blok e 3 Connection plate Page 56 ...
Страница 86: ...Termostroj Croatia APPENDIX 6 Termo Extra e 2 Electric sketch Termo Extra e 3 Connection plate Page 59 ...
Страница 89: ...Termostroj Croatia APPENDIX 7 Termo Blok m 2 Electric sketch Termo Blok m 3 Connection plate Page 62 ...
Страница 92: ...Termostroj Croatia APPENDIX 8 Termo Extra m 2 Electric sketch Termo Extra m 3 Connection plate Page 65 ...