2. Using control panels
2.1. Working with standard control panel
Standard electromechanical control panel
The automatics consists of the following elements:
1 – Indicator of temperature /pressure in boiler
2 – Working thermostat
3 – Switch for the 2
nd
and 3
rd
operation stage
4 – Cutout thermostat with manual deactivation (switches off on ca 115
o
C)
5 – Indicator of air appearance in the boiler - air-indicator (also indicates low voltage protection)
6 - Switch for ON/OFF and the 1
st
heating stage
7 – Fuse 2,5A protecting the pump and switches
8 – Indication of heater operation
9 - Indicates low voltage protection - under 180V
Putting on central heating
By switching the switch (6) ON, the central heating system is switched on and the first power stage is
active. With switch (3) it is possible to control manually the second or the third power stage of boiler.
Boilers with 3 stages have soft start for the second and the third stage and switches (3) have only
limiting function. If the boiler is heating, the light of heater in operation (8) is on, if heaters are not
working and boiler is in standby only ON/OFF light is on.
Adjustment of desired temperature of central heating
With the help of working thermostat (2) it is possible to select the fixed desired temperature in boiler.
Working thermostat has range from 20ºC to 80ºC. Recommended temperature is about 60ºC (12
o’clock position).
Air in the boiler (5), red light
If the air appears in the boiler, the signalization of air in the boiler turns on (5) and the boiler stops the
operation. In this way the boiler is protected against burning through due to presence of air. To
continue the operation the boiler should be vented. If the boiler is correctly vented, the operation of
boiler continues automatically.
Voltage drop (9), red light
If the voltage in the network line drops below 180V by phase, the signalization of under voltage
protection (9) turns on, the boiler automatically switches off in order to protect electronics and
INSTALACIJSKE UPUTE
Zadržavamo pravo izmjene uputa bez posebne najave
Содержание TERMO-Blok
Страница 2: ...TMS UT 0114 T03 1 INSTRUCTIONS FOR USE We reserve the right of alternations ...
Страница 25: ...TMS UT 0114 T01 1 INSTRUCTIONS FOR INSTALLATION We reserve the right of alternations ...
Страница 66: ...TMS UT 0114 T01 1 Page 39 ...
Страница 76: ...Termostroj Croatia APPENDIX 3 Termo Blok PTV m 2 Electric sketch Termo Blok PTV m 3 Connection plate Page 49 ...
Страница 83: ...Termostroj Croatia APPENDIX 5 Termo Blok e 2 Electric sketch Termo Blok e 3 Connection plate Page 56 ...
Страница 86: ...Termostroj Croatia APPENDIX 6 Termo Extra e 2 Electric sketch Termo Extra e 3 Connection plate Page 59 ...
Страница 89: ...Termostroj Croatia APPENDIX 7 Termo Blok m 2 Electric sketch Termo Blok m 3 Connection plate Page 62 ...
Страница 92: ...Termostroj Croatia APPENDIX 8 Termo Extra m 2 Electric sketch Termo Extra m 3 Connection plate Page 65 ...