TMS-UT-0114-T01-1
contactors inside the boiler. The boiler will automatically continue the operation when the network
voltage reaches values above 180V.
Cutout thermostat - turning on
Cutout thermostat (safety thermostat) (8) protects the boiler against rapid increase of temperature
above 115°C. The fuse turns the boiler off and ejects the RCCB (RCD)-switch.
For the continuation of operation it is necessary to take off the protection cover from the cutout
thermostat and press the red key, upon which the RCCB (RCD)-switch should be switched on again.
5.6. Working with electronic control panels
(option C and W and Termo Blok PTV)
5.6.1. General
Regardless of the selected regulation curve the maximum water temperature in the boiler is limited to
90°C for radiator heating and 50°C for floor heating.
Factory setting of the curve is 1,5 for radiator heating.
Factory setting of the curve is 0,6 for underfloor heating.
Refer to chapter 1.4. for detailed description of heating curves.
Refer to chapter 1.5. for detailed description of DHW functions.
Refer to chapter 1.6. for detailed description of frost protection.
Refer to chapter 4.8 for detailed description of selecting a desired set of heating curves.
Part n umb er: 1659
4
0
2
bar
52
12
11
1
2
3
4
5
6
0
I
7
Type 1 – Outdoor temperature compensation
Page 28
Содержание TERMO-Blok
Страница 2: ...TMS UT 0114 T03 1 INSTRUCTIONS FOR USE We reserve the right of alternations ...
Страница 25: ...TMS UT 0114 T01 1 INSTRUCTIONS FOR INSTALLATION We reserve the right of alternations ...
Страница 66: ...TMS UT 0114 T01 1 Page 39 ...
Страница 76: ...Termostroj Croatia APPENDIX 3 Termo Blok PTV m 2 Electric sketch Termo Blok PTV m 3 Connection plate Page 49 ...
Страница 83: ...Termostroj Croatia APPENDIX 5 Termo Blok e 2 Electric sketch Termo Blok e 3 Connection plate Page 56 ...
Страница 86: ...Termostroj Croatia APPENDIX 6 Termo Extra e 2 Electric sketch Termo Extra e 3 Connection plate Page 59 ...
Страница 89: ...Termostroj Croatia APPENDIX 7 Termo Blok m 2 Electric sketch Termo Blok m 3 Connection plate Page 62 ...
Страница 92: ...Termostroj Croatia APPENDIX 8 Termo Extra m 2 Electric sketch Termo Extra m 3 Connection plate Page 65 ...