2.3.2. Central heating functions
>5 sec
0.6
41
>5 sec
>10 sec
>5 sec
3
32
>5 sec
<5 sec
>15 sec
>5 sec
90
>20 sec
60
32
>5 sec
Display of desired temperature inside the boiler
By pressing the key (6) user can see the desired temperature inside the
boiler.(calculated from the selected correction curve)
The Display shows the desired temperature of water in the boiler. The value
is displayed for 5 s, after which display normally shows the real temperature
of water in the boiler.
Correction curve selection
By pressing the key (6) user can enter curve selection menu.
The number of set curve is blinking, according to which the correction of
water temperature in the boiler is corrected in relation to external
temperature. Values are between 1 and 3 or 0,2 and 0,9. Curves between 1
and 3 are for radiators’ central heating and curves 0,2 to 0,9 are for under
floor heating.
By pressing the key, numbers of curves are changing with the step of 0,1
within the set, according to the diagram on the front plate. If the key is held
pressed less than 5 s the display value becomes valid regulation curve.
Limiting maximum boiler power
By pressing the key (6) user can limit the power level.
By pressing the key it is possible to select 1 2 or 3 as number of available
power levels. If the key is held pressed less than 5 s the selected power
level mode will become active.
Boilers from 6 to 16 kW have only two power levels.
Limiting maximum temperature inside the boiler
By pressing the key (6) user can limit maximum temperature inside the
boiler.
Factory defined maximum temperature starts to blink. By pressing up or
down user can set new maximum temperature. If the key (6) is held pressed
less than 5 s the selected maximum temperature will become active.
This temperature represents maximum temperature that can be
achieved regardless of selected curve.
Manual selection of desired temperature inside the boiler
By pressing the key (6) user can set temperature in the boiler, regardless of
previously selected curve.
Desired temperature starts to blink. By pressing the key up or down user
can select fixed temperature in the boiler. If the key is held pressed less
than 5 s the fixed temperature becomes active.
When boiler is in fixed temperature mode, the LED display blinks while
displaying current temperature in the boiler. User can just press the key (6)
up or down for next change of fixed temperature.
When boiler is in fixed temperature mode, all correction curves are
disregarded. To return to the correction curve mode, the boiler must
be switched off and back on using ON/OFF switch.
INSTALACIJSKE UPUTE
Zadržavamo pravo izmjene uputa bez posebne najave
Содержание TERMO-Blok
Страница 2: ...TMS UT 0114 T03 1 INSTRUCTIONS FOR USE We reserve the right of alternations ...
Страница 25: ...TMS UT 0114 T01 1 INSTRUCTIONS FOR INSTALLATION We reserve the right of alternations ...
Страница 66: ...TMS UT 0114 T01 1 Page 39 ...
Страница 76: ...Termostroj Croatia APPENDIX 3 Termo Blok PTV m 2 Electric sketch Termo Blok PTV m 3 Connection plate Page 49 ...
Страница 83: ...Termostroj Croatia APPENDIX 5 Termo Blok e 2 Electric sketch Termo Blok e 3 Connection plate Page 56 ...
Страница 86: ...Termostroj Croatia APPENDIX 6 Termo Extra e 2 Electric sketch Termo Extra e 3 Connection plate Page 59 ...
Страница 89: ...Termostroj Croatia APPENDIX 7 Termo Blok m 2 Electric sketch Termo Blok m 3 Connection plate Page 62 ...
Страница 92: ...Termostroj Croatia APPENDIX 8 Termo Extra m 2 Electric sketch Termo Extra m 3 Connection plate Page 65 ...