TMS-UT-0114-T01-1
Recommended pressure of central heating installation is 0,15 mpa (1,5 bar), maximum pressure is
0,25 mpa (2,5 bar).
3.3. Recommendations for various installation types
Following flow chart is provided in order to help installers choosing the right type of boiler for desired
installation type. At the end of each tree is the number of corresponding appendix. Each appendix
consists of the following: the hydraulic drawing, a typical electrical drawing, the description of
connection plate, the description of control panel, and the description of the complete central heating
system.
Central heating
type
Control panel
Central heating
and hot water
Central
heating
Instalation
type
Electronic
control panel
Basic
control panel
Termo-Blok PTV-e
Appendix - 1
or
Termo-Extra-e
Appendix - 2
Termo-Extra-e
Appendix - 2
New installation
Existing installation
Instalation
type
Termo-BlokPTV-m
Appendix - 3
or
Termo-Extra-m
Appendix - 4
Termo-Extra-m
Appendix - 4
New installation
Existing installation
Control panel
Instalation
type
Electronic
control panel
Basic
control panel
Termo-Blok-e
Appendix - 5
or
Termo-Extra-e
Appendix - 6
Termo-Extra-e
Appendix - 6
New installation
Existing installation
Instalation
type
Termo-Blok-m
Appendix - 7
or
Termo-Extra -m
Appendix - 8
Termo-Extra-m
Appendix - 8
New installation
Existing installation
Note:
These installation samples should not be used as the detailed installation plan. Before
installation observe the local regulations.
3.4. Installation site
3.4.1. Position of a boiler
The location must provide adequate space for servicing and air circulation around the boiler. The
boiler may be installed in any room, although particular attention is drawn to the local regulations in
respect to the installation of a boiler in a room containing a bath or a shower. The boiler must be
mounted on a flat, vertical wall, which must be sufficiently robust to bear the weight of the boiler. The
Page 15
Содержание TERMO-Blok
Страница 2: ...TMS UT 0114 T03 1 INSTRUCTIONS FOR USE We reserve the right of alternations ...
Страница 25: ...TMS UT 0114 T01 1 INSTRUCTIONS FOR INSTALLATION We reserve the right of alternations ...
Страница 66: ...TMS UT 0114 T01 1 Page 39 ...
Страница 76: ...Termostroj Croatia APPENDIX 3 Termo Blok PTV m 2 Electric sketch Termo Blok PTV m 3 Connection plate Page 49 ...
Страница 83: ...Termostroj Croatia APPENDIX 5 Termo Blok e 2 Electric sketch Termo Blok e 3 Connection plate Page 56 ...
Страница 86: ...Termostroj Croatia APPENDIX 6 Termo Extra e 2 Electric sketch Termo Extra e 3 Connection plate Page 59 ...
Страница 89: ...Termostroj Croatia APPENDIX 7 Termo Blok m 2 Electric sketch Termo Blok m 3 Connection plate Page 62 ...
Страница 92: ...Termostroj Croatia APPENDIX 8 Termo Extra m 2 Electric sketch Termo Extra m 3 Connection plate Page 65 ...