1.4.2. About Heating curves
The modern way of heating is based on energy saving and automatic adjustments to warm up the
space.
To achieve the required temperature electric boiler with electronic control panel heats the water in the
boiler automatically depending on the external temperature. There is no need to look after the minimal
working temperature because electric boilers do not dew and that means that the temperature of the
water in the boiler is at the same time the temperature in the heating elements (for example in
radiators, convectors etc.).
To achieve the desired room temperature, the characteristic heating curve has to be chosen
depending on the characteristics of the object and the heating system.
Factory defined curves
If the heating curve is set optimally for heating of your apartment or house, corrections will not
be necessary.
1.4.3. Why does the characteristic heating curve have to be set?
After the first settings of the heating curve authorized person can adjust, correct that curve if
necessary.
Every heating room is built up differently. Different heating elements and heating systems can be used
(radiators, under floor or combined heating) and every building has a different thermal insulation.
For the maximum exploitation of the heating and maximum energy savings, characteristic heating
curve has to be set using the parameter on the control panel, in a way that the chosen heating curve is
suitable for the heating system and for the quality of the building.
1.4.4. Corrections of the room temperature
Based on the experience, factory settings of the device are for the average insulated object and room
temperature of 22
o
C. If factory settings are not adequate for achieving the desired room temperature,
supplemental adjustments of the standard heating curves can be made.
Changing the inclination
When changing the heating curve, inclination is changing too, and in that way the temperature of
water in the boiler is changing when the external temperature is low (below+ 5
o
C).
Level changes - offset
By offsetting the heating curve for the chosen value the temperature of water in the boiler is changing
without changing the shape of the curve.
Page 2
Содержание TERMO-Blok
Страница 2: ...TMS UT 0114 T03 1 INSTRUCTIONS FOR USE We reserve the right of alternations ...
Страница 25: ...TMS UT 0114 T01 1 INSTRUCTIONS FOR INSTALLATION We reserve the right of alternations ...
Страница 66: ...TMS UT 0114 T01 1 Page 39 ...
Страница 76: ...Termostroj Croatia APPENDIX 3 Termo Blok PTV m 2 Electric sketch Termo Blok PTV m 3 Connection plate Page 49 ...
Страница 83: ...Termostroj Croatia APPENDIX 5 Termo Blok e 2 Electric sketch Termo Blok e 3 Connection plate Page 56 ...
Страница 86: ...Termostroj Croatia APPENDIX 6 Termo Extra e 2 Electric sketch Termo Extra e 3 Connection plate Page 59 ...
Страница 89: ...Termostroj Croatia APPENDIX 7 Termo Blok m 2 Electric sketch Termo Blok m 3 Connection plate Page 62 ...
Страница 92: ...Termostroj Croatia APPENDIX 8 Termo Extra m 2 Electric sketch Termo Extra m 3 Connection plate Page 65 ...