![Tennant T600e Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/tennant/t600e/t600e_service-information-manual_1087319065.webp)
65
T600/T600e 9016605 (04-2018)
TROUBLESHOOTING
T600 / T600e ec-H2O NANOCLEAN ICON FAULTS
Flashing
service
indicator
Flashing
LED fault
code
Membrane Control Panel
Pro-Panel Controls (LCD)
Fault code
xxxxxx
Flashing service indicator
Press icon to access fault
code screen
Fault code screen
Red or yellow ec-H2O
fault icon
Solid or
blinking Red
ec-H2O
indicator
LED Fault
Code and
Icon
☼
= Flashing
LCD Fault
Code
(T600
Only)
Fault Condition
Cause
Correction
●
☼
☼
☼
●
0x0704
ec-H2O CAN
Communication
Fault
1. Control boards are not
communicating properly.
2. Board lost power (wiring issue)
3. Control board may be
damaged.
4. ec-H2O connector unplugged
(never plugged in).
5. ec-H2O connector pin 2 or 3
disconnected.
6. ec-H2O connector power pin
disconnected.
1. Power cycle machine.
2. No communication with a network
module.
3. Check connections / wiring.
0x0704
ec-H2O CAN
Communication
Fault
1. Board lost power or CAN
connection (wiring issue)
2. ec-H2O board may be
damaged.
3. ec-H2O connector unplugged.
4. ec-H2O connector pin 2 or 3
disconnected.
1. Power cycle machine.
2. No communication with a network
module.
3. Check connections / wiring.
●
☼
●
☼
●
0x0711
ec-H2O Pump
Open Fault
1. ec-H2O pump wiring,
connector or control board issue.
Control board is not detecting pump
current. Check connections for
voltage and verify if pump is operating.
●
☼
☼
☼
☼
0x0713
ec-H2O Pump
Over Current
Fault
1. Current draw higher than
expected.
Check pump operating current.
☼
●
●
●
●
0x0707
ec-H2O
Cartridge Expired
1. ec-H2O water cartridge has
expired due to either gallons of
usage or 2 years of use.
1. Replace ec-H2O water cartridge.
☼
●
☼
●
●
0x0703
ec-H2O Circuit
Breaker Tripped
Warning
1. Detected module circuit
breaker trip.
2. Scrub controller board J6
connector unplugged.
3. Scrub controller board J6
connector pin 1 disconnected.
Reset breaker. Power cycle machine.
Check connector / wire connections.
0x0712
ec-H2O Pump
Circuit Breaker
Tripped
1. Detected module circuit
breaker trip.
2. Scrub controller board J6
connector unplugged.
3. Scrub controller board J6
connector pin 1 disconnected.
Reset breaker. Power cycle machine.
Check connector / wire connections.
Содержание T600e
Страница 13: ...T600 T600e 9016605 04 2018 13 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 1 1 2 3 5 4...
Страница 14: ...14 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 2 1 2 3 5 4...
Страница 15: ...T600 T600e 9016605 04 2018 15 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 3 1 3 2...
Страница 16: ...16 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 4 1 2 3...
Страница 17: ...T600 T600e 9016605 04 2018 17 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 1 1 2 3 5 4...
Страница 18: ...18 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 2 1 2 3 5 4...
Страница 19: ...T600 T600e 9016605 04 2018 19 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 3 1 2...
Страница 20: ...20 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 4 1 2...
Страница 137: ...137 T600 T600e 9016605 04 2018 SERVICE...
Страница 150: ...150 T600 T600e 9016605 04 2018 SERVICE Hinge assembly Cable Recovery tank Hinge assembly Solution tank...