T600/T600e 9016605 (04-2018)
MAINTENANCE
BATTERIES
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off machine,
and remove key.
Your machine is equipped with either fl ooded (wet)
lead-acid or maintenance-free (Sealed AGM) batteries
supplied by Tennant.
The lifetime of the batteries depends on proper
maintenance. To get the most life from the batteries:
•
Do not charge the batteries more than once a day
and only after running the machine for a minimum
of 15 minutes.
•
Do not leave the batteries partially discharged for
long period of time.
•
Only charge the batteries in a well-ventilated area
to prevent gas build up.
•
Allow the charger to complete charging the
batteries before re-using the machine.
•
Maintain the proper electrolyte levels of fl ooded
(wet) batteries by checking battery cell levels
weekly.
FOR SAFETY: When servicing machine, battery
installation must be done by trained personnel.
FOR SAFETY: When servicing machine, keep all
metal objects off batteries. Avoid contact with
battery acid.
MAINTENANCE-FREE BATTERIES
Maintenance-free (Sealed AGM) batteries do
not require watering. Cleaning and other routine
maintenance is still required.
FLOODED (WET) LEAD-ACID BATTERIES
The fl ooded (wet) lead-acid batteries require routine
watering as described below. Check the battery
electrolyte level weekly.
NOTE: If machine is equipped with the automatic
or manual battery watering system, proceed to the
BATTERY WATERING SYSTEM instructions.
The electrolyte level should be slightly above the
battery plates as shown before charging. Add distilled
water if low. DO NOT OVERFILL. The electrolyte
will expand and may overfl ow when charging. After
charging, distilled water can be added up to about
3 mm (0.12 in) below the sight tubes.
Before Charging
After Charging
CHECKING CONNECTIONS / CLEANING
After every 200 hours of use, check for loose battery
connections and clean the surface of the batteries,
including terminals and cable clamps to prevent
battery corrosion. Use a scrub brush with a strong
mixture of baking soda and water. Do not remove
battery caps when cleaning batteries.
Содержание T600e
Страница 13: ...T600 T600e 9016605 04 2018 13 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 1 1 2 3 5 4...
Страница 14: ...14 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 2 1 2 3 5 4...
Страница 15: ...T600 T600e 9016605 04 2018 15 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 3 1 3 2...
Страница 16: ...16 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 4 1 2 3...
Страница 17: ...T600 T600e 9016605 04 2018 17 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 1 1 2 3 5 4...
Страница 18: ...18 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 2 1 2 3 5 4...
Страница 19: ...T600 T600e 9016605 04 2018 19 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 3 1 2...
Страница 20: ...20 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 4 1 2...
Страница 137: ...137 T600 T600e 9016605 04 2018 SERVICE...
Страница 150: ...150 T600 T600e 9016605 04 2018 SERVICE Hinge assembly Cable Recovery tank Hinge assembly Solution tank...