61
T600/T600e 9016605 (04-2018)
TROUBLESHOOTING
BDI (Battery
Discharge
Indicator)
☼
= Flashing
Pro-Panel
LCD Faults
(T600 Only)
Fault Condition
Reason
Correction
☼
●
☼
☼
●
0x0107
Scrub Motor 1 FET
Fault
1. Control board problem.
2. Power / battery issue on startup.
Replace control board.
0x0117
Scrub Motor 2 FET
Fault
1. Control board problem.
2. Power / battery issue on startup.
Replace control board.
0x0207
Actuator FET Fault
1. Control board problem.
2. Power / battery issue on startup.
Replace control board.
0x0307
Valve FET Fault
1. Control board problem.
2. Power / battery issue on startup.
Replace control board.
0x0507
Vacuum FET Fault
1. Control board problem.
2. Power / battery issue on startup.
Replace control board.
0x0607
Detergent Pump
FET Fault
1. Control board problem.
2. Power / battery issue on startup.
Replace control board.
0x0617
Wand Pump FET
Fault
1. Control board problem.
2. Power / battery issue on startup.
Replace control board.
0x0B17
Battery Watering
Pump FET Fault
1. Control board problem.
2. Power / battery issue on startup.
Replace control board.
☼
●
☼
☼
☼
0x0503
Vacuum Over Cur-
rent Fault
1. Current draw higher than expected.
Check harness and vacuum.
0x0504
Vacuum Over Cur-
rent 1 Fault
1. Current draw higher than expected.
Verify vacuum load, damage
and / or usage conditions.
0x0505
Vacuum Over Cur-
rent 2 Fault
1. Current draw higher than expected.
Verify vacuum load, damage
and / or usage conditions.
0x0506
Vacuum Shorted
Load Fault
1. Shorted load condition.
2. Some higher current draw than
hardware design limit.
Check harness and vacuum.
☼
☼
●
●
●
0x0613
Wand Pump Over
Current Fault
1. Current draw higher than expected.
2. Some higher current draw than
hardware design limit.
Check harness and pump.
0x0614
Wand Pump Over
Current 1 Fault
1. Current draw higher than expected.
Verify wand pump load, dam-
age and / or usage condi-
tions.
0x0615
Wand Pump Over
Current 2 Fault
1. Current draw higher than expected.
Verify wand pump load, dam-
age and / or usage condi-
tions.
0x0616
Wand Pump Short
Fault
1. Shorted load condition.
2. Some higher current draw than
hardware design limit.
Check wire harness and
repair as needed.
☼
●
●
●
●
0x0611
Wand Pump Open
Warning
1. Wiring, connector or control board
issue on the wand pump.
Verify wand pump is con-
nected to machine harness
and pump is functional.
☼
☼
●
●
☼
0x0603
Detergent Pump
Over Current Fault
1. Current draw higher than expected.
Check harness and pump.
0x0604
Detergent Pump
Over Current 1 Fault
1. Current draw higher than expected.
Verify detergent pump load,
damage and / or usage
conditions.
Содержание T600e
Страница 13: ...T600 T600e 9016605 04 2018 13 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 1 1 2 3 5 4...
Страница 14: ...14 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 2 1 2 3 5 4...
Страница 15: ...T600 T600e 9016605 04 2018 15 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 3 1 3 2...
Страница 16: ...16 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 4 1 2 3...
Страница 17: ...T600 T600e 9016605 04 2018 17 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 1 1 2 3 5 4...
Страница 18: ...18 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 2 1 2 3 5 4...
Страница 19: ...T600 T600e 9016605 04 2018 19 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 3 1 2...
Страница 20: ...20 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 4 1 2...
Страница 137: ...137 T600 T600e 9016605 04 2018 SERVICE...
Страница 150: ...150 T600 T600e 9016605 04 2018 SERVICE Hinge assembly Cable Recovery tank Hinge assembly Solution tank...