60
T600/T600e 9016605 (04-2018)
TROUBLESHOOTING
BDI (Battery
Discharge
Indicator)
☼
= Flashing
Pro-Panel
LCD Faults
(T600 Only)
Fault Condition
Reason
Correction
☼
●
●
☼
☼
0x0103
Scrub Motor 1 Hard-
ware Over Current
Fault
1. Current draw higher than expected.
2. Some higher current draw than
hardware design limit.
Verify fl oor, pad, and down
pressure combination are
appropriate for machine.
Check actuator.
0x0104
Scrub Motor 1 Soft-
ware Over Current
Fault
1. Current draw higher than expected.
Verify fl oor, pad, and down
pressure combination are
appropriate for machine.
Check actuator.
0x0105
Scrub Motor 1 Over
Current 2 Fault
1. Current draw higher than expected.
Verify fl oor, pad, and down
pressure combination are
appropriate for machine.
Check actuator.
0x0106
Scrub Motor 1 Short
Fault
1. Shorted load condition.
2. Some higher current draw than
hardware design limit.
Check wire harness and
repair as needed.
0x0109
Scrub Motor 1 Over
Heat Fault
1. Motor is drawing too much current
and is overheating.
Inspect scrub brushes to see
if they are completely worn. If
scrub brushes are not worn,
motor is defective. Replace
scrub motor.
☼
☼
●
☼
☼
0x0113
Scrub Motor 2 Hard-
ware Over Current
Fault
1. Current draw higher than expected.
2. Some higher current draw than
hardware design limit.
Verify fl oor, pad, and down
pressure combination are
appropriate for machine.
Check actuator.
0x0114
Scrub Motor 2 Soft-
ware Over Current
1 Fault
1. Current draw higher than expected.
Verify fl oor, pad, and down
pressure combination are
appropriate for machine.
Check actuator.
0x0115
Scrub Motor 2 Over
Current 2 Fault
1. Current draw higher than expected.
Verify fl oor, pad, and down
pressure combination are
appropriate for machine.
Check actuator.
0x0116
Scrub Motor 2 Short
Fault
1. Shorted load condition.
2. Some higher current draw than
hardware design limit.
Check wire harness and
repair as needed.
0x0119
Scrub Motor 2 Over
Heat Fault
1. Motor is drawing too much current
and is overheating.
Inspect scrub brushes to see
if they are completely worn.
If scrub brushes are not
worn and head is not orbital
head, motor is defective.
Replace scrub motor. If head
is orbital, eccentric or motor
might be bad.
☼
●
☼
●
☼
0x0902
Propel High Throttle
Fault
1. Bail is activated before turning on
machine.
2. Bail did not release to full rest posi-
tion due to obstruction.
Release bail or bail ob-
struction before turning on
machine.
Содержание T600e
Страница 13: ...T600 T600e 9016605 04 2018 13 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 1 1 2 3 5 4...
Страница 14: ...14 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 2 1 2 3 5 4...
Страница 15: ...T600 T600e 9016605 04 2018 15 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 3 1 3 2...
Страница 16: ...16 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 4 1 2 3...
Страница 17: ...T600 T600e 9016605 04 2018 17 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 1 1 2 3 5 4...
Страница 18: ...18 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 2 1 2 3 5 4...
Страница 19: ...T600 T600e 9016605 04 2018 19 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 3 1 2...
Страница 20: ...20 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 4 1 2...
Страница 137: ...137 T600 T600e 9016605 04 2018 SERVICE...
Страница 150: ...150 T600 T600e 9016605 04 2018 SERVICE Hinge assembly Cable Recovery tank Hinge assembly Solution tank...