996227
27
The MFA will perform a test on itself and the connected sensors every time the engine is started. If
one of the connected sensors is defective, the text “SENS” will appear in the display.
The table below shows the critical and alarm values for the A80.
Critical value
Alarm value
Engine temperature
98°C
103°C
Hydraulic fluid temperature
95°C
103°C
Water tank level
100 litres
14 litres (extra margin
50L)
Fuel tank level
18 litres
4 litres
Table 4: Critical and alarm values
Setting and accepting the time
To set the time:
•
Simultaneously press keys B and 9 for five seconds.
The displayed time, for instance 10:35 will blink in the display.
•
Repeatedly press keys A, B, 9 and 10 to set the time. Key A for position 1 ("1"), key B for
position 2 ("0"), key 9 for position 3 ("3") and key 10 for position 4 ("5").
Every time you press the key, the corresponding number is increased by the value 1.
To accept the newly set time:
•
Keep key B depressed.
•
Press key 9 until the time stops blinking.
•
Release both keys.