EN
OPERATION
2100/2120/2140/2150/2200/2260 (07–03)
10
TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
Machine does not
Faulty power cord.
Contact Service Center.
operate.
Tripped circuit breaker. (2200/2260 Models)
Reset circuit breaker on machine. Allow
machine to cool down for approximately
5–10 minutes.
Tripped building circuit breaker.
Reset circuit breaker in building.
Faulty machine wiring.
Contact Service Center.
Faulty On/Off lever switch.
Contact Service Center.
Faulty motor.
Contact Service Center.
The cord connection between the handle and
base is not correctly inserted.
Ensure correct cord connection.
Machine operates
Soiled Pad.
Replace Pad.
with a wobble or jerky
motion.
Improper pad/brush for application
Change to proper pad/brush.
motion.
Pad driver/brush not installed correctly.
Remove and reinstall pad driver/brush.
Pad/brush unevenly worn.
Replace pad/brush.
Pad not properly centered.
Remove and reinstall pad.
Machine circuit
Heavily soiled pad/brush.
Clean or replace pad/brush.
breaker trips
continuously.
Improper pad/brush for application.
Change to proper pad/brush.
continuously.
(2200/2260 models)
Defective circuit breaker.
Contact Service Center.