Cyclone User Manual
44
System Manager Installation
Connect the enclosure(s) to a Windows PC running Windows 10 or later,
using the diagram above.
For more information on connecting enclosures using RS485, see the next
section.
Note that Tempest System Manager is an operating mode of GetSet MV, a
software application written and marketed by Tempest’s electronics
partner JESE.
You will need to download GetSet MV from JESE’s web
portal:
https://www.jese.co.uk/support/
Use the Serial Number and Check ID from the RDM-TXI to log in:
IMPORTANT!
Do not connect any JESE USB device in to your windows PC before installing
the software.
Doing so may cause windows to install the incorrect USB
driver for your device and prevent normal operation of the software.
JESE GetSet is licensed software and registered to a qualifying hardware
component. Qualifying components include a USB controller such as an
RDM-TRI or RDM-TXI.
The software license is perpetual and includes one year of updates and
feature additions. Further updates and supports are available from JESE
with an annual subscription fee.
Having installed GetSet, connect the RDM-TXI to the PC using the provided
USB cable, and then launch the application.
Network Configuration
By default, EtherNode modules are configured for network DHCP
addressing. In the absence of a DHCP service, modules will default to an
address in 10.0.0.0/8 network range until a DHCP address is assigned. The
default address may be determined by translatin
g a modules’ Serial
Number to an address greater than $10 00 00 00. For instance, a Serial