![TeleEye GN8 Series Скачать руководство пользователя страница 84](http://html1.mh-extra.com/html/teleeye/gn8-series/gn8-series_user-manual_1081105084.webp)
TeleEye GN8916/GN8932/GN8816/GN8616 User Guide Page 79
Physical Configuration for System Tamper
The system tamper input and ground of TeleEye GN8 HD digital video recorder have to connect to
an external cabinet which is used for protecting the digital video recorder and its accessories
[Main Menu] → [Event Handler] → [System Tamper]
Enable
Enable / disable system tamper event
Sensor Type
Select circuit open/close as normal state
Action
Set actions taken when system tamper is triggered
5.4.3.7.Power Failure
It is an input to the digital video recorder typically used for wiring the output signal pin from an
uninterruptible power supply (UPS).
Physical Configuration for Power Failure Input
The power failure input and ground of TeleEye GN8 digital video recorder have to connect to a
universal power supply circuit UPS in order to detect any power failure.
The UPS circuit setup above is used as an example. Not all UPS have signal output. Some UPS
have self-testing occasionally. Their signal output may toggled during tests.
UPS provides backup
power and sends a
power failure signal
to GN8 when the
main power does
not work ordinarily.