![TeleEye GN8 Series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/teleeye/gn8-series/gn8-series_user-manual_1081105014.webp)
TeleEye GN8916/GN8932/GN8816/GN8616 User Guide Page 9
and with similar disk size. The function can be found in the OSD menu:
[Main Menu] → [HDD/Recording] → [Disk Management] → [RAID Se ng]
.
RAID5
Enable / Disable RAID
RAID Spare Disk
No. of spare disk
2.5. RAID Status
RAID status will be shown in
[Disk Management]
after restart. Recording data will have
redundancy when RAID status is NORMAL.
RAID Status
Current RAID Status
NORMAL : RAID is running normally
DEGRADED : RAID is degraded, requires rebuild
REBUILDING* : RAID is doing recover / re-sync
Disk Status
Current Disk Status
RAID-RECORDING : this disk is doing recording in RAID
SPARE : this disk is a spare for RAID
REBUILDING : this disk is doing building
•
Time for rebuilding RAID is depending on HDD size. For HDD with 2TB size, typical rebuild time is about 1.5
days
2.6. RAID Action Case
Action
Result
Rebuilding in progress
Rebuilding Complete
Remove 1 HDD:
RAID-RECORDING
RAID Status: FAIL, not enough disk
for raid
RAID Rebuilding:
RAID rec.: recording fail
Playback: playback fail
RAID Status: REBUILDING, SPARE:
0/1
RAID Rebuilding: rebuilding starts
again
RAID rec.: recording normal
Playback: playback normal
Remove 1 HDD:
REBUILDING
RAID Status: DEGRADED, SPARE:
0/1
RAID Rebuilding: rebuilding starts
NA