Introduction to integrator parameters
Parameter name Description
Mode
Standard
It allows user to define a period of Set Time for
integrator measurement, which ranges from 1
second to 9999 hours, 59 minutes and 59 seconds.
Manual
User is not able to define a Set Time. The
integrator measurement will be running
constantly till Stop button is pressed by user.
Continuous
Partly identical with the Standard mode, the
integrator measurement runs for a cycle of the
Set Time and repeats the cycle indefinitely until
Stop button is pressed by user.
Function
Watt Hours
WP: Total power
WP+: Positive total
power
WP-: Negative total
power
P(avg): Average
power