T3PM1100 User Manual
148
[:INPut]:VOLTage:AUTO
Description
Sets or returns the voltage auto range on/off state.
Syntax
[:INPut]:VOLTage:AUTO {<Boolean>|OFF|ON}
Query Syntax
[:INPut]:VOLTage:AUTO?
Parameter
<Boolean>0 OFF
<Boolean>1 ON
Return parameter 0
Turn the voltage auto range function off.
1
Turn the voltage auto range function on.
Example
:INPUT:VOLTAGE:AUTO ON
:INPUT:VOLTAGE:AUTO?
->:INPUT:VOLTAGE:AUTO 1
[:INPut]:VOLTage:CONFig
Description
Sets or returns the valid voltage range.
Syntax
[:INPut]:VOLTage:CONFig {ALL|<Voltage>[,Voltage]…}
Query Syntax
[:INPut]:VOLTage:CONFig?
Parameter/
Return parameter
ALL
All ranges are valid.
<Voltage> See(:INPut:VOLTage:RANGe).
Example
:INPUT:VOLTAGE:CONFIG 300,150,30
:INPUT:VOLTAGE:CONFIG?
->:INPUT:VOLTAGE:CONFIG 300.0E+00,150.0E+00,
30.0E+00
[:INPut]:VOLTage:POJump
Description
Sets or returns the jump destination range that is
used when a voltage peak over-range occurs.
Syntax
[:INPut]:VOLTage:POJump {OFF|<Voltage>}
Set
Query
Set
Query
Set
Query
Содержание Everywhereyoulook T3PM1100
Страница 1: ...T3PM1100 Digital Power Meter User Manual ...
Страница 75: ...MEASUREMENT AND OTHER FUNCTIONS 75 3 Press ESC button to return back to original display mode ESC ...
Страница 119: ...COMMAND OVERVIEW 119 CR LF The most common EOL character is CR LF Message Separator EOL or semicolon Command Separator ...
Страница 191: ...COMMAND OVERVIEW 191 Example STATUS QMESSAGE ON STATUS QMESSAGE STATUS QMESSAGE 1 ...
Страница 209: ...APPENDIX 209 Status system The diagram below is a description of the status system ...
Страница 213: ...APPENDIX 213 Dimensions Units mm ...