BLZZRD Portable Refrigerated Sampler
Section 5 Extended Programming
5-31
If you select COMPLETE SAMPLES, the sampler sends a
three-second pulse only after it successfully collects a sample.
The sampler will not send an event mark if an error occurs, such
as “No Liquid Detected.”
Figure 5-5 Event Mark Timing Diagram
If you select EVERY SAMPLE, the sampler will send an event
mark every time a sample is initiated. The event mark signal can
be a:
•
3-second pulse at the beginning of the pre-sample purge.
•
3-second pulse at the beginning of forward pumping
only, marking the time the sampler deposited the
sample.
•
Variable duration pulse generated during the pump
cycle, from the beginning of the pre-sample purge to the
end of the postsample purge.
•
Variable duration pulse generated only during forward
pumping.
Figure 5-5 shows event mark timing diagrams.
Bottle Number
–
Concurrent with the event mark, the sampler
also sends a bottle number signal. The bottle number signal is a
series of pulses. The number of pulses sent represents the bottle
currently accepting a sample (see Figure 5-5).
5.15.8 Pre-sample and
Post-sample Purge
Counts
The pre-sample purge is when the pump runs in reverse clearing
the strainer of any debris before taking a sample. The pre-sample
purge is set at 200 pump counts. After the sample is taken a
post-sample purge occurs to clear the liquid from the suction line.
Presample Purge
Rinse Cycle
Pump Volume 1
Pump Volume 2
Pump Volume 3
Postsample Purge
Event Mark
Event Mark
Bottle Number
Event Mark
Bottle Number
Bottle Number
Pulse at Beginning of
Presample Purge
Pulse at Beginning of
Forward Pumping
Variable Duration Pulse
During Entire Pump
Event Mark
Bottle Number
Variable Duration Pulse
During Forward
Pumping
This diagram shows the pulses sent for a bottles-per-sample distribution scheme
Содержание Everywhereyoulook BLZZRD
Страница 2: ......
Страница 4: ......
Страница 8: ...BLZZRD Portable Refrigerated Sampler Safety vi ...
Страница 16: ...BLZZRD Portable Refrigerated Sampler Table of Contents xiv ...
Страница 34: ...BLZZRD Portable Refrigerated Sampler Section 1 Introduction 1 18 ...
Страница 58: ...BLZZRD Portable Refrigerated Sampler Section 2 Installation Preparation 2 24 ...
Страница 72: ...BLZZRD Portable Refrigerated Sampler Section 3 Programming Introduction 3 14 ...
Страница 88: ...BLZZRD Portable Refrigerated Sampler Section 4 Standard Programming 4 16 ...
Страница 219: ...BLZZRD Portable Refrigerated Sampler Appendix B Material Safety Data Sheets B 8 ...
Страница 233: ...BLZZRD Portable Refrigerated Sampler Appendix D Replacement Parts D 6 ...
Страница 241: ...BLZZRD Portable Refrigerated Sampler Appendix F Battery Selection Guide F 4 ...