TCM260904
Rev
0.1
TCM260904
Page 21 of 31
D Save
Power 1.
3 min.
2.
30 sec, 1 min,
90 sec, 2 min
3 min, 4 min,
5 min, Not execute
“Save Power”:
The transmitter will turn off the power
supply automatically if there is no operation for a certain
time, in order to save power. Only the transmitter is in the
“continuous transmitting” mode is this function available..
E Alarm mode 1. Simple alarm mode
2. Morse alarm mode
“Simple alarm mode”:
If the self-diagnostic detects a
malfunction then the buzzer will sound to indicate the
error message, one long sound means Encoder module
malfunction, two long sounds mean transmitter RF module
malfunction, three long sounds mean power supply
malfunction. During operation this mode is used to
indicate a fault situation.
“Morse alarm mode”:
There are 5 kinds of Morse code
to report a detailed error message. Normally this mode is
used to indicate individual malfunctioning parts.
F Password 1.
No
2. Yes
This item is used to set the password function. The
operator
has to enter the password before turning on the
transmitter if
“Yes”
is selected. This function is like an
electronic-key that can prevent unauthorized persons from
operating the remote controller.
“Password entry procedure”:
When the EMS mushroom
is in the “off” (pulled up) position and the rotary key
switch is in the ‘on” position, press the pushbuttons
sequentially to enter the password (During the password
entry period, “Password Complete”, the LED indicator
will flash green). The transmitter buzzer will sound one
long beep if password is correct. After buzzer turns off,
power-on according to the proper procedure and return to
normal operation. If the password is incorrect then the
buzzer will sound with two short beeps and one long beep
(“
•
•
−
”). Enter the correct password again after buzzer
turns off.
G Password
set
1.
By pushbutton
2.
By software
If the password function is set as “Yes” then the Password
code can be set by pushbutton or by software.
Setting password by pushbutton:
Depress the EMS mushroom and turn the rotary key
switch to the “off” position.
Depress and hold both “UP” & “DOWN” pushbuttons and
then turn the rotary key switch from “off” to “on” position
simultaneously. At this time, the LED will flash red and
green alternately for 10 seconds.
Press the pushbuttons sequentially to key in a new
password within 10 seconds. The buzzer will sound three
long beeps when the password setting procedure is
finished. The length of the password is four-digits, for
example: Up, Up, Down, Up.
Pull up EMS mushroom and enter new password to turn
on transmitter.
This function is designed for authorized and qualified
operators to set or change the password if they forget the
original one. Because other people do not understand this
procedure, it can prevent unauthorized persons from
operating the remote controller.
“Setting password by software”:
It means that the
password can only be set by software.