TCM260904
Rev
0.1
TCM260904
Page 22 of 31
H E.U.
Start 1.
EU (Standard)
2.
EU (Simple)
“E.U. Start”:
If “E.U.(standard)” is selected is the mode
for “Power-On”, when the EMS signal is automatically
sent out by the Transmitter and the Main Relay in the
Receiver is turned off in the auto off mode, to start the
“Power-On” operation again by the Transmitter, if “E.U.
(Standard)” is selected , one must turn the rotary key
switch to the positions ON
→
OFF
→
ON
→
START
in
order
to set the receiver to “Power-On” mode, if “E.U.
(Simple)” is selected only rotate the rotary key switch” to
the “Start” position to “Power-On” the Receiver.
Note:
“Auto Off” means that the Transmitter will turn off
the power supply automatically if there is no operation for
a certain time. If “E.U.(standard) is selected for the
“Power-On”, mode, to turn the rotary key switch
according to the positions ON
→
OFF
→
ON
→
START
in
order to “Power-On” the Receiver after the EMS
mushroom is pressed.
I
Normal OP 1. LED-off
2. LED-on
“LED-off”:
The LED indicator will be shut off during
normal operation in order to save power. But it is still
available for warning and fault indication.
“LED-on”:
LED indicator will light up green when
transmitter is transmitting. It is still available for warning
and fault indication with first priority.
J Password
Complete
1.
10 Seconds
2.
4, 5, 10, 15, 20, 25,
30, 40, 50, 60 sec.
“Password Complete”:
If the password function is
selected, this function determines the time to enter the
password. If the password is not entered within the
password complete time, it must be re-entered from the
beginning.