TCM260904
Rev
0.1
TCM260904
Page 23 of 31
O
THER
R
ECEIVER
F
UNCTIONS
:
Item Title
Options
Description
A Auto Off
1. 1 hour
2. 10 minutes
20 minutes
30 minutes
1 hour
2 hours
3 hours
4 hours
not execute
“Receiver Auto Power-Off”:
If the receiver doesn’t
receive the correct control data within a certain time, then
the Stop relay on the receiver will be de-energized
automatically (i.e. receiver Power-Off). Normally this
function is used with the “non-continuous transmitting
mode” to shut the crane off if the operator forgot to turn
off the transmitter.
B Function
dip
1.
Enable
2.
Disable
“Function DIP”:
This setting determines whether the DIP
switch on the Receiver/Decoder module of Receiver is
used to set functions. If “
Disable”
is selected, then the
function setting is fully controlled by software.
C Alarm mode 1. Simple alarm mode
2. Morse alarm mode
“Simple alarm mode”:
If the self-diagnostic detects a
malfunction then the alarm will sound to indicate the error
message, one long sound means Relay module
malfunction, two long sounds mean Receiver/Decoder
module malfunction, three long sounds mean power
failure. During operation, this mode is used to indicate
fault situation.
“Morse alarm mode”:
There are 22 kinds of Morse code
to report a detailed error message. Normally this mode is
used to indicate individual malfunctioning parts.
D Acc. delay 1.
2 sec.
2.
0 sec, 0.5 sec
1 sec, 1.5 sec
2 sec, 3 sec
4 sec
“Acceleration delay time”:
This function is used to set
the time interval between acceleration relays closing. It is
used for accelerating operations only in order to prevent
the crane from running directly to the highest speed which
can damage the motor.
E Channel
DIP
1.
Enable
2.
Disable
“Channel Dip”:
This setting determines whether the DIP
switch on the Receiver/Decoder module of the Receiver is
used to set the channel. If
“Disable”
is selected, then the
channel setting is fully controlled by software.