TCM260904
Rev
0.1
TCM260904
Page 29 of 31
20.
Y
—
•
— —
Interference by the same model of remote
controller
Change to a new frequency
21.
1
•
— — — —
Interference by another radio signal on the
same frequency.
If interference is not serious, “Power-
On” the remote controller when the
interference is over.
If interference is serious, change to
new frequency. (Refer to section 4-4-4
at operator’s Manual)
22.
Z
— —
•
•
E
2
PROM in the Receiver/ decoder doesn’t
have function setting s or settings are
incomplete.
Contact distributor for programming of
function settings.
Note:
(1)
When the receiver’s self-diagnostics detect a malfunction, the alarm will continue, until the
malfunction has been corrected or the power to the receiver is disconnected.
(2)
The receiver can be set by the software to sound the alarm or not, when an error occurs
relating to item 20 ~ 21.
(3)
The receiver can be set by software to stop the affected action (i.e. “Relay-Off”) or
“Power-Off” automatically, when the error occurs relating to items 20 ~ 21. For the other
items, the receiver will enter into the Auto Power-Off mode.
(4)
This receiver contains an Automatic Gain Control circuit with high sensitivity; when not in
operation, it may receive weak signals from unknown sources. As long as the interference
does not occur very often, it will not affect the normal operation. No frequency change is
necessary.