TCM260904
Rev
0.1
TCM260904
Page 16 of 31
FUNCTION SETTING
The operation of the controller can be modified to suit a specific application, using a PC with a special interface cable.
For further information please contact your distributor.
S
TART
S
WITCH
F
UNCTION
S
ETTING
:
Item Title
Options
Description
A Function 1.
No Function
2.
Alarm
3.
Normal
4.
Toggle
This function is available only when remote controller is
in “Power-On” mode.
“Alarm”:
The alarm relay will close and the receiver
alarm will sound if the rotary key switch is rotated to the
“Start” position, and the alarm relay will turn off when the
rotary key switch is released.
“Normal”:
The associated relay is “on” when the
pushbutton is pressed and held, and is “off” when the
pushbutton is released.
“Toggle”:
Press the pushbutton and release once for “on”,
re-press and release for “off”.
U
P
/D
OWN
P
USHBUTTON
F
UNCTION
S
ETTING
:
Item Title
Options
Description
A Interlock 1.
Interlock
2.
Non-Interlock
“Interlock”:
If the motions cannot be operated
simultaneously then select “Interlock”.
“Non-Interlock”:
If the motions are allowed to operate
simultaneously then select “Non-Interlock”.
This item is selectable only when UP and DOWN
pushbuttons are set at “Normal” function.
UP: DOWN:
1. Normal
Normal
2. Toggle
Normal
3. Toggle
Toggle
B Function
4. On
Off
“Normal”:
The associated relay is “on” when the
pushbutton is pressed and held, and is “off” when the
pushbutton is released.
“Toggle”:
Press the pushbutton and release once for “on”,
re-press and release for “off”.
“ON & OFF”:
The two pushbuttons are set to
respectively control the same relay. If a pushbutton set as
“on” is pressed and released, then the relay remains
closed. No other pushbutton can change the status of this
relay except the pushbutton set as “off”.