Checks and Adjustments
1705A Spectrum Monitor
5- 7
c.
Connect the leveled sine wave generator output to the comb generator.
Connect the comb generator output to the 1705A rear-panel 70 MHz
INPUT. See Figure 5-1.
2.
Check Power Supply Operation
REQUIREMENT —
Check ac input range, 90 -- 250 V.
a.
Set the leveled sine wave generator Frequency to 5.0 MHz, the
Amplitude Multiplier to X1, and the Amplitude to 4.0 (+16 dBm).
b.
Adjust the controls for a usable display.
c.
Vary the autotransformer from low-line to high-line voltage (90 - 132 V
for 110 V, or 180 - 250 V for 220 V operation).
d. CHECK
--
f
or stable operation over the prescribed voltage range. (Note:
If the LNB POWER is on and in use, the requirement is derated to 100 --
132 V or 200 -- 250 V.)
e.
Return the autotransformer to the local nominal mains voltage.
3.
Check LNB Power Supply
REQUIREMENT —
+18 Vdc
±
5%.
a.
Connect DVM leads between the center conductor of the L--BAND
INPUT connector and ground.
b.
Turn on the LNB POWER switch.
c.
CHECK
--
t
hat the rear-panel, LNB POWER LED is ON, and that the
DVM reads +18 V
±
0.9 V.
d.
Temporarily (approximately 2 seconds) short the L--BAND INPUT
connector center conductor to ground.
e.
CHECK
--
t
hat the red indicator lamp extinguishes and then comes back
on when the short is removed.
f.
Turn LNB POWER off.
CAUTION.
The LNB POWER switch MUST be turned off for the rest of this
procedure to prevent damage to the generators used in later steps.
4.
Check 70 MHz Linearity
REQUIREMENT —
One marker per Division
±
1 minor Division.
Содержание 1705A
Страница 13: ...Service Safety Summary xii 1705A Spectrum Monitor ...
Страница 17: ...Preface xvi 1705A Spectrum Monitor ...
Страница 18: ...Introduction ...
Страница 19: ......
Страница 38: ...Operating Instructions ...
Страница 39: ......
Страница 61: ......
Страница 62: ...Installation ...
Страница 63: ......
Страница 72: ...Theory of Operation ...
Страница 73: ......
Страница 93: ...Theory of Operation 4 20 1705A Spectrum Monitor ...
Страница 94: ...Checks and Adjustments ...
Страница 95: ......
Страница 123: ...Checks and Adjustments 5 28 1705A Spectrum Monitor ...
Страница 124: ...Maintenance ...
Страница 125: ...Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 FAX 781 665 0780 TestEquipmentDepot com ...
Страница 154: ...Options ...
Страница 155: ......
Страница 158: ...Replaceable Electrical Parts ...
Страница 159: ......
Страница 189: ...Replaceable Electrical Parts 8 30 1705A Spectrum Monitor ...
Страница 190: ...Diagrams Circuit Board Illustrations ...
Страница 191: ......
Страница 193: ......
Страница 213: ......
Страница 214: ...Replaceable Mechanical Parts ...
Страница 215: ......
Страница 223: ......