TEK-CPCI-1003 Technical Reference Manual
8-8
8.4.3 Thermal Management
The thermal management is built around two digital temperature sensors and a thermal
watchdog. Both devices can be programmed to set their outputs when the temperature of
the processor or the ambient temperature exceeds a programmable high limit, and reset its
output when the temperature is under a programmable low limit. A special routine is
implemented to throttle the CPU clock until the temperature falls below the programmed
low limit.
Please refer to Section 12.3.5 –
Thermal Management Setup
for a complete information
thermal management setups.