ISOBUS ECU 1224 User and Instruction maual
|
P00801545 Rev:02 SW:1.0.0
24
ISO-15
ISO-20
Custom 1
(*)
Custom 2
(*)
Main valve type
Type of main valve
Bypass
Dump
Main valve driver
How the main valve is managed
Independent
Dependent
Regulation valve type
Define what time of regulation valve
is installed in the control unit
Bypass (3 ways)
Throttling (2 ways)
Section valve type
Section valve type
ON-OFF
OFF-ON
ON-OFF met.
OFF-ON met.
Section valve wires
Number of Wires for each valve
2 Wires: Polarity inversion
3 Wires : Power and driving pin.
Note: Require correct type of
harness.
2 or 3
Sections control
Modify the way section valves are
manually opened/closed (refer
Chapter 10.4 for a description of
these parameters)
Standard
Extended
Tank level sensor present
Tank level sensor presence/absence
yes/no (check box)
Reserve level
Number of liters of the tank reserve
0 ÷ 10000
Tank capacity
Tank capacity in liters
0 ÷ 20000
Offset Y
(**)
Distance of the center of the spray
bar, relative to the center axis facing
in the direction of movement (mm)
–
positive if moved to the right and
negative when moved to the left
-100,00 ÷ 100,00
Содержание GEOline 8410073
Страница 1: ......
Страница 57: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 56 17 DECLARATION OF CONFORMITY Figure 41 ...
Страница 58: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 57 18 ISOBUS CERTIFICATION Figure 42 ...
Страница 63: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 62 ...
Страница 64: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 63 ...
Страница 65: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 64 ...
Страница 66: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 65 ...
Страница 67: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 66 ...
Страница 68: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 67 ...