ISOBUS ECU 1224 User and Instruction maual
|
P00801545 Rev:02 SW:1.0.0
48
12
TROUBLESHOOTING
Table 14
DISPLAY
CAUSE
SOLUTION
The display does not turn on
There is not power.
Check the connections on the
power cable.
The indicator is turned off.
Press the turning on button.
The valves can not be controlled
The valves are not connected.
Connect the connectors
A valve does not open
The valve has not power.
Check the electric connection
and the functioning of the valve
The counter of the travelled
distance shown on the computer
is different from the real one.
Wrong programming
Check the speed sensor
configuration.
The reset of the treatment has
not been effectuated
Reset the treatment
The counter of the travelled
surface shown on the computer
is different from the real one.
Wrong programming
Check the bar width
programming
The reset of the treatment has
not been effectuated
Reset the treatment
The instant pressure is not
shown.
The indicator has not signal from
the pressure sensor
Check the connections with the
pressure sensor
Wrong installation of the pressure
sensor
Check the bottom scale
programming for the pressure
sensor
The instant pressure visualized is
inaccurate.
Wrong programming
Check the bottom scale
programming for the pressure
sensor
Wrong installation of the pressure
sensor
Check the connections with the
pressure sensor
The tank level visualized is
inaccurate.
The level sensor is not calibrated. Do the calibration.
Repeat the level sensor
calibration.
Wrong installation of the level
sensor.
Check the connection with the
level sensor
Led L1 (refer to figure 22) is
always Off
The ECU-1224 has an hardware
or software problem
Call the technical support
Led L2 (refer to figure 22) is
always Off
The ECU-1224 has an hardware
or software problem
Call the technical support
Led L2 (refer to figure 22)
remains always On (doesn’t
flash) when the ECU is
connected to the ISOBUS
network
Problems on ISOBUS network
connection
Verify that your Virtual Terminal
is correctly installed and turned
on.
If the problem persists, call the
technical support.
Leds L4 and L5 (refer to figure
22) remains always Off.
The ECU-1224 is not correctly
powered.
Check the ECU-1224 connection
cable.
Содержание GEOline 8410073
Страница 1: ......
Страница 57: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 56 17 DECLARATION OF CONFORMITY Figure 41 ...
Страница 58: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 57 18 ISOBUS CERTIFICATION Figure 42 ...
Страница 63: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 62 ...
Страница 64: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 63 ...
Страница 65: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 64 ...
Страница 66: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 65 ...
Страница 67: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 66 ...
Страница 68: ...ISOBUS ECU 1224 User and Instruction maual P00801545 Rev 02 SW 1 0 0 67 ...