Random lockout time
When the
“Door random bit” event triggers on a Network Access Controller door
(which can occur if the door’s
Random event %
setting is non-zero), then there
is a new setting which locks out the door for a specified amount of time, called
Random % lockout time
. The lockout time can also be specified as indefinite.
During this time, the door can only be opened by users
with the “Privileged” flag;
the door cannot be opened by any other users.
Any LCD RAS attached to the door will display “Locked Out”.
Note:
Users with the “Privileged” flag cannot cause a door lockout.
A door’s random lockout time can be programmed in CTPlus on the
Access
tab
of the
Doors/Lifts
form. See the “Random % lockout time” section on page 69.
LED area mapping for door readers
Note:
LED area mapping does not apply in IP Direct mode.
It is possible to map the LEDs on door readers to specific areas, in the same way
as can be done for a Challenger
Plus
RAS.
The LED area mapping is programmed in the
Door reader
dialog, accessed from
the
Readers
tab of the
Doors/Lifts
form. See the “Door reader dialog – LED
” section on page 66.