Figure 7 Door / Lift creation wizard
The wizard has the following fields:
Panel Click the Browse button on the right of the field to select the panel to add a
door or lift to.
Access type
Whether to add a Door or Lift to the panel.
Controller type Select the type pf the controller that the door or lift will be added
as part of:
Panel
The door of lift will be added directly to the Challenger Panel as a standard door
or a standard lift. A RAS will be created if necessary.
Dual Weigand Interface
The door or lift will be added to the Challenger Panel as a standard door or a
standard lift. A DGP of type Dual Wiegand Interface will be created if necessary.
V8 Door/Lift Controller
The door or lift will be added to as a part of a Four-Door controller as a V8 door
or a Four-lift Controller as a V8 lift. A DGP of the appropriate type will be created
if necessary.
Network Access Controller
The door will be added as part of NAC as a NAC door. A DGP of type Network
Access Controller will be created if necessary.
Device no
The first device number for the door or lift will be added. Standard doors are
numbered in the range 1 to 2.Standard lifts are numbered in the range 1 to
16.NAC doors for a NAC in Classic mode or IP Extended mode, V8 doors, and
V8 lifts are numbered in the range 17 to 64, or 81 to 128.NAC door for a NAC in
Содержание TS1066