![TECOM TS1066 Скачать руководство пользователя страница 100](http://html1.mh-extra.com/html/tecom/ts1066/ts1066_programming-manual_1072587100.webp)
To configure a door override in CTPlus, click the
Door override
button on the
Operation
ribbon tab to open the Door override form:
Each door on a NAC has a door override record. The
Record
description field
contains the name of the door.
When finished configuring the door override, click the
Save
button in the
toolbar to save the record.
Panel
In the case of a NAC in IP Direct or IP Extended mode, the field will show the
NAC connection.
In the case of a NAC in Classic mode, the field will show the Challenger
Plus
panel the NAC is connected to.
Setup tab
Times
Each door override record contains one to eight sub-time zones. A start time and
end time must be programmed for at least the first sub-time zone:
Start time:
The start time requires an hour, minute, and AM or PM to
indicate when the sub-time zone begins.
End time:
The end time is programmed in the same way as the start time
to indicate when the sub-time zone ends.
Содержание TS1066
Страница 1: ...TS1066 Network Access Controller Programming Manual P N MAPROG TS1066 REV 1 6 ISS 16AUG19 ...
Страница 4: ...ii TS1066 Network Access Controller Programming Manual APPENDIX B Enclosure Access Restrictions 106 ...
Страница 6: ......
Страница 36: ...See Status and control section for more details depending on the operating mode of NAC ...