6-34
Communication
Address
Parameter
Name & Function
Default Unit
Setting
Range
Control
Mode
RS232
RS485
DI-1 Active Level
Setting Explanation
0
Low Active (short with IG24)
★
Hn601.2
1 High
Active
X
0
│
1
ALL C23H
0501H
DI-2
★
Hn602
Please refer to
Hn601
X
001
│
11F
ALL C24H
0502H
DI-3
★
Hn603
Please refer to
Hn601
X
001
│
11F
ALL C25H
0503H
DI-4
★
Hn604
Please refer to
Hn601
X
001
│
11F
ALL C26H
0504H
DI-5
★
Hn605
Please refer to
Hn601
X
001
│
11F
ALL C27H
0505H
DI-6
★
Hn606
Please refer to
Hn601
X
001
│
11F
ALL C28H
0506H
DI-7
★
Hn607
Please refer to
Hn601
X
001
│
11F
ALL C29H
0507H
DI-8
★
Hn608
Please refer to
Hn601
X
001
│
11F
ALL C2AH
0508H
DI-9
★
Hn609
Please refer to
Hn601
X
001
│
11F
ALL C2BH
0509H
DI-10
★
Hn610
Please refer to
Hn601
X
001
│
11F
ALL C2CH
050AH
DI-11
★
Hn611
Please refer to
Hn601
X
001
│
11F
ALL C2DH
050BH
DI-12
★
Hn612
Please refer to
Hn601
Refer to
the cross
reference
table on
page
5-65
X
001
│
11F
ALL
C2EH
050CH
★
New setting will become effective after re-cycling the power.
Warning!
If any of programmable Inputs of DI-1 ~ DI-13 are set for the same type of function
then the logic state selection ( NO or NC selection) for these inputs must be the same type.
Otherwise an Alarm will be displayed. AL-07 (Abnormal DI/DO programming).
Содержание JSDAP Series
Страница 1: ......
Страница 17: ...1 11 1 2 Surface and Panel Board JSDAP 10A 15A 20A 30A JSDAP 50A3 75A3 100A3 25B 35B 50B ...
Страница 21: ...1 15 1 4 2 Direction and Distance ...
Страница 25: ...2 2 400V Class ...
Страница 98: ...5 12 PA PB PZ 90 PA PB PZ 90 TIME A leads B CW CCW B leads A TIME ...
Страница 236: ...9 5 Dimensions for JSDAP 150A3 75B 100B Dimensions for JSDAP 200A3 300A3 ...
Страница 249: ...A 1 Appendix A Accessories ...
Страница 250: ...A 2 ...
Страница 251: ...A 3 ...
Страница 255: ......