6-3
Communication
Address
Parameter
Name & Function
Default Unit
Setting
Range
Control
Mode
RS232 RS485
Output time setting for Mechanical Brake Signal
Cn003
Brake Signal Timing Sequence
:
1
1
1
Cn003 (machinery brake signal output time) is negative
Cn003 (machinery brake signal output time)
Input Contacts SON
Servo ON
Output Contacts BI
Implementation a pin for dynamic brake signal(BI) as a
output signal before to perform this function. Refer to
sequence diagram above.
Note: Signal logic level status: 1 = ON. 0 = OFF.
Refer to section5-6-1 for setting contact the high &
Low logic levels.
0 msec
-2000
│
2000
ALL 511H 0003H
Motor rotate direction.(Inspect from the load
side)
CCW
CW
When Torque or Speed Command value is Positive, the
setting of Motor retation direction are:
Explanation
Setting
Torque Control
Speed Control
0
Counter
ClockWise(CCW)
Counter
ClockWise (CCW)
1 ClockWise
(CW)
Counter
ClockWise (CCW)
2
Counter
ClockWise (CCW)
ClockWise(CW)
Cn004
3
ClockWise (CW)
ClockWise (CW)
0 X
0
│
3
S
T
512H 0004H
Содержание JSDAP Series
Страница 1: ......
Страница 17: ...1 11 1 2 Surface and Panel Board JSDAP 10A 15A 20A 30A JSDAP 50A3 75A3 100A3 25B 35B 50B ...
Страница 21: ...1 15 1 4 2 Direction and Distance ...
Страница 25: ...2 2 400V Class ...
Страница 98: ...5 12 PA PB PZ 90 PA PB PZ 90 TIME A leads B CW CCW B leads A TIME ...
Страница 236: ...9 5 Dimensions for JSDAP 150A3 75B 100B Dimensions for JSDAP 200A3 300A3 ...
Страница 249: ...A 1 Appendix A Accessories ...
Страница 250: ...A 2 ...
Страница 251: ...A 3 ...
Страница 255: ......