5-45
5-4-8 Homing Function
Homing function is used to find and set a reference point for correct positioning.
To set a HOME reference position, one of input contacts ORG (external sensor input), CCWL, or CWL
can be used.
An encoder Z phase (marker pulse) can also be used as home reference and can be search by CW or
CCW direction. Following Home routine selections are available for setting parameter Pn 365.0.
Parameter
Name
Setting
Description
Control
Mode
0
Once the home routine is activated, motor will search for Home
Position switch in 1
st
preset speed in
CCW
direction
.
Input contacts CCWL or CWL can be used as the Home Reference
Switch.
Once Home reference switch is detected and complete, input contacts
CCWL
and
CWL
will act as limits input contact again.
Note:
When using this function, 1 or 2 setting of
Pn317.1
is not allowable.
Cn002.1 (
CCWL & CWL Input terminal function
) must to set as 0.
1
Once the home routine is activated, motor will search for Home
Position switch in 1
st
preset speed in
CW direction.
Input contacts CCWL or CWL can be used as the Home Reference
Switch.
Once Home reference switch is detected and complete, input contacts
CCWL
and
CWL
will act as limits input contact again.
Note:
When using this function, 1 or 2 setting of
Pn317.1
is not allowable.
Cn002.1 (
CCWL & CWL Input terminal function
) must to set as 0.
2
Once the home routine is activated , motor will search for Home
Position switch in 1
st
preset speed in
CCW direction
and sets the input
contact ORG (external sensor input) as a Home reference when ORG
contact is activated.
If
Pn317.1=2
, it will directly find the closest Rising-Edge of
ORG
to be the Home position (without a need for Home reference),then it
stops in accordance with
Pn317.3
setting.
3
Once the home routine is activated , motor will search for Home
Position switch in 1
st
preset speed in
CW direction
and sets the input
contact ORG (external sensor input) as a Home reference when ORG
contact is activated.
If
Pn317.1=2
, it will directly find the closest Rising-Edge of
ORG
to be the Home position (without a need for Home reference),then it
stops in accordance with
Pn317.3
setting.
4
Once the home routine is activated , motor will search for Home
position in 1st preset speed in
CCW
direction and sets the Home
reference
Servo drive start to find the Home position of the nearest Z phase.
(No need for Home reference)
When using this function, set
Pn317.1=2
.
After finished setting of
Z
Phase to the Home position, for the stop
method refer to the setting of
Pn317.3.
Pn317.0
On activation of
Home input
contact,
It sets the
search
direction
and Home
reference.
(Setting for
home routine)
5
Once the home routine is activated , motor will search for Home
position in 1st preset speed in
CW
direction and sets the Home
reference
Servo drive start to find the Home position of the nearest Z phase.
(No need for Home reference)
When using this function, set
Pn317.1=2
.
After finished setting of
Z
Phase to the Home position, for the stop
method refer to the setting of
Pn317.3.
Pi/Pe
Содержание JSDAP Series
Страница 1: ......
Страница 17: ...1 11 1 2 Surface and Panel Board JSDAP 10A 15A 20A 30A JSDAP 50A3 75A3 100A3 25B 35B 50B ...
Страница 21: ...1 15 1 4 2 Direction and Distance ...
Страница 25: ...2 2 400V Class ...
Страница 98: ...5 12 PA PB PZ 90 PA PB PZ 90 TIME A leads B CW CCW B leads A TIME ...
Страница 236: ...9 5 Dimensions for JSDAP 150A3 75B 100B Dimensions for JSDAP 200A3 300A3 ...
Страница 249: ...A 1 Appendix A Accessories ...
Страница 250: ...A 2 ...
Страница 251: ...A 3 ...
Страница 255: ......