5-38
4. Parameter Setting for Electronic Gear Ratio
Setting gear ratio Numerator and denominator parameters:
Numerator and denominator values of the calculated electronic gear ratio must be entered in the
required parameters.
These two values have to be integer and with a value within the specified range in the table below.
Parameter
Signal
Name
Default
Unit
Setting
Range
Control
Mode
Pn302
Numerator of Electronic Gear Ratio 1
1
X
1~50000
Pi/Pe
Pn303
Numerator of Electronic Gear Ratio 2
1
X
1~50000
Pi/Pe
Pn304
Numerator of Electronic Gear Ratio 3
1
X
1~50000
Pi/Pe
Pn305
Numerator of Electronic Gear Ratio 4
1
X
1~50000
Pi/Pe
★
Pn306
Denominator of Electronic Gear Ratio
1
X
1~50000
Pi/Pe
★
New setting will become effective after re-cycling the power.
This device provides 4 selections of Numerator for Electronic Gear Ratio.
Input contacts
GN1
and
GN2
can be used to select the required Numerator for the Electronic Gear
Ratio
According to the following table.
Input
Contact GN2
Input Contact
GN1
Numerator of Electronic Gear Ratio
Control
Mode
0 0
Numerator of Electronic Gear Ratio 1
Pn302
0 1
Numerator of Electronic Gear Ratio 2
Pn303
1 0
Numerator of Electronic Gear Ratio 3
Pn304
1 1
Numerator of Electronic Gear Ratio 4
Pn305
Pi/Pe
Note: Input contacts status “1” (ON) and “0” (OFF)
Please check 5-6-1 to set the required high /Low signal levels (PNP/NPN) selection.
Содержание JSDAP Series
Страница 1: ......
Страница 17: ...1 11 1 2 Surface and Panel Board JSDAP 10A 15A 20A 30A JSDAP 50A3 75A3 100A3 25B 35B 50B ...
Страница 21: ...1 15 1 4 2 Direction and Distance ...
Страница 25: ...2 2 400V Class ...
Страница 98: ...5 12 PA PB PZ 90 PA PB PZ 90 TIME A leads B CW CCW B leads A TIME ...
Страница 236: ...9 5 Dimensions for JSDAP 150A3 75B 100B Dimensions for JSDAP 200A3 300A3 ...
Страница 249: ...A 1 Appendix A Accessories ...
Страница 250: ...A 2 ...
Страница 251: ...A 3 ...
Страница 255: ......