2-19
Digital Output Function Explanation
(The terminal layout here from this explanation are all the low electric potential, please refer to 5-6-1 to check
parameter settings)
Signal Name
Function
Symbol
Mode
I/O Function
Servo Ready
RDY
ALL
Main power and control power input are normal. Under the
situation of no alarm, terminal layouts
RDY
and
IG24
close
loop.
Alarm
ALM
ALL
If normally operates, the terminal layouts
ALM
and
IG24
open
loop. When alarm occurs, protection-function operates, the
terminal and
IG24
close loop.
Zero Speed
ZS
S
When the motor speed is less than the speed from
Sn215,
the
terminal layout
ZS
and
IG24
close loop.
BK Signal
BI
ALL
When
Cn008
is set “1” or “3” and the servo on, the terminal
layout
BI
and
IG24
close loop; when servo off , terminal layout
and
IG24
open loop. (When this terminal layout is generally
applied, it is the Brake relay, which is connected to control
motor).
In Speed
INS
S
When the motor speed has achieved the setting speed from
Cn007,
INS
and
IG24
close loop.
In Position
INP
Pi/Pe
When the amount of position error counter is less than the
amount range which is set in
Pn307, INP and IG24
close loop.
Home
HOME
Pi/Pe When HOME is accomplished,
HOME
and
IG24
close.
Torque Reach
signal
INT
ALL
When the output torque reached the setting value of Tn108,
INT
and IG24 close
.
Limiting Torque/
Alarm No. 0
LM/A0
ALL
When motor output torque is limited by internal torque limit
amount (
Cn010&Cn011)
or external torque limit command
(
PIC&NIC)
.
LM/A0
and
IG24
close loop.
When alarm occurs, this terminal layout is alarm code output
A0
.
P in Action /
Alarm No.1
PC/A1
Pe/Pi/S
When speed loop is ratio(P)-control,
PC/A1
and
IG24
close
loop.
When alarm occurs, this terminal layout is alarm code output
A1
.
Server in Limiting/
Alarm No.2
ST/A2
ALL
When CCW or CW operation-limit occurs,
ST/A2
and
IG24
close loop.
When alarm occurs, this terminal layout is alarm code output
A2
Base Block/
Alarm No.3
BB/A3
ALL
When servo motor has not be operated,
BB/A3
and
IG24
close
loop.
When alarm occurs, this terminal layout is alarm code output
A3
Содержание JSDAP Series
Страница 1: ......
Страница 17: ...1 11 1 2 Surface and Panel Board JSDAP 10A 15A 20A 30A JSDAP 50A3 75A3 100A3 25B 35B 50B ...
Страница 21: ...1 15 1 4 2 Direction and Distance ...
Страница 25: ...2 2 400V Class ...
Страница 98: ...5 12 PA PB PZ 90 PA PB PZ 90 TIME A leads B CW CCW B leads A TIME ...
Страница 236: ...9 5 Dimensions for JSDAP 150A3 75B 100B Dimensions for JSDAP 200A3 300A3 ...
Страница 249: ...A 1 Appendix A Accessories ...
Страница 250: ...A 2 ...
Страница 251: ...A 3 ...
Страница 255: ......