5-66
5-6-2 Switch for the Control Mode
Set one of the programmable input terminals to MDC (Control mode) selection.
The input then will select the preset control mode, which is set by Parameter Cn001.
Selections are listed
below:
Parameter
Name
Setting
Description
Control
Mode
MDC Input off
MDC Input On
3
Position Control
(External Pulse Command)
Speed Control
4
Speed Control
Torque Control
5
Position Control
(External Pulse Command)
Torque Control
7
Position Control
(Internal Pulse Command)
Speed Control
8
Position Control
(Internal Pulse Command)
Torque Control
★
●
Cn001
Control Mode
Selection
A
Position Control
(Internal Pulse Command)
Position Control
(External Pulse
Command)
ALL
New setting will become effective after re-cycling the power.
Please check 5-6-1 to setting the input contact required high /Low signal levels (PNP/NPN
selection).
5-6-3 Auxiliary Functions
Function of Input Contacts SON, CCWL and CWL can be set according to the list below:-
Parameter
Name
Setting
Description
Control Mode
0
Use input contact
SON
to switch Servo On
。
★
Cn002.0
SON
(Servo ON )
1
Servo on with Power on.
SON
input contact not required
.
ALL
0
CCWL
and
CWL(external limits) are effective.
CCW and CW rotation is inhibited by
CCWL&CWL.
Cn002.1
CCWL
and
CWL
(Counter Clockwise
&
Clockwise Limits)
1
CCWL
and
CWL(external limits) are
ineffective.
CCW&CW rotation is not limited by
CCWL&CWL.
ALL
New setting will become effective after re-cycling the power.
Содержание JSDAP Series
Страница 1: ......
Страница 17: ...1 11 1 2 Surface and Panel Board JSDAP 10A 15A 20A 30A JSDAP 50A3 75A3 100A3 25B 35B 50B ...
Страница 21: ...1 15 1 4 2 Direction and Distance ...
Страница 25: ...2 2 400V Class ...
Страница 98: ...5 12 PA PB PZ 90 PA PB PZ 90 TIME A leads B CW CCW B leads A TIME ...
Страница 236: ...9 5 Dimensions for JSDAP 150A3 75B 100B Dimensions for JSDAP 200A3 300A3 ...
Страница 249: ...A 1 Appendix A Accessories ...
Страница 250: ...A 2 ...
Страница 251: ...A 3 ...
Страница 255: ......