4
-
148
Please refer to Figure 4.3.46 for the automatic restart operation.
t
07-18
( When 07-00 = 1 , the fault contact is active )
t
t
Figure 4.3.46 Auto-restart operation
The automatic restart function is active for the following faults. Please note that when the fault is not listed
in the table the inverter will not attempt an automatic restart.
Parameter
Name
Faults
Numbers of
Restart
07-00
UV
(under voltage)
Unlimited
07-01
07-02
OC
(over current)
OCA
(over current in ACC.)
OCC
(over current in
constant speed)
OCd
(over current in DEC)
OL1
(motor overload)
UT
(Under torque detection)
IPL
(input phase loss)
GF
(ground failure)
OV
(overvoltage)
OL2
(Inverter overload)
OT
(Over-torque detection)
OPL
(Output phase loss)
CF07
(SLV motor control
setting fault)
CF08
(PMSLV motor
control setting fault)
Depend on
parameter
07-02
Notes:
1.
Fault restart function contains momentary power loss restart and auto reset restart.
2.
Refer to chapter 10 for the details of troubleshooting and fault diagnostics.
3.
Refer to speed search function (07-19~07-24) for the selection of speed search modes.
Note:
Automatic restart function is only active in the state of no harm to the safety or to the application devices.
Warning - Excessively use of the automatic restart function will damage the inverter.
07- 04
Automatic start at power up
Range
【
0
】
:
Automatic start at power up when external run command is enabled
【
1
】
:
Without automatic start at power up when external run command is enabled
07- 04 = 0:
If the running switch is in conducting state when power supply is on, the inverter will start automatically.
07- 04 =1:
If the running switch is not in conducting state when power supply is on , the inverter will not start
automatically and STP1 will flash. It is required to switch off the running switch and make it be in
conducting state so as to start the inverter.
Содержание F510 Series
Страница 1: ......
Страница 42: ...3 31 200V 150 175HP 400V 300 425HP Terminal screw size T M12 M10 400V 530 800HP Terminal screw size T M10 M10 ...
Страница 46: ...3 35 200V 150 175HP 400V 300 425HP Terminal screw size T M12 M10 400V 530 800HP Terminal screw size T M10 M10 ...
Страница 282: ...4 210 Frequency 1 11 72 Frequency 2 11 73 Output Frequency 11 69 Gain of Preventing Oscillation 3 0 ...
Страница 434: ...11 10 Dimensions of LED LCD keypad IP20 Figure 11 5 2 Dimensions of LED keypad ...
Страница 444: ...Ver 02 2019 09 ...