ATA Energy Storage System MM
49
User’s manual
02
Maximum charging current:
To configure total charging
current for solar chargers.
(If selected “SNU” into
parameter 16 the max.
charging current = utility
charging c solar
charging current)
10A
20A
30A
40A
50A
60A
(default)
70A
80A
90A
100A
110A
120A
03
AC input voltage range
Appliances
If selected, acceptable AC input
voltage range will be within 90-
280VAC.
UPS
(default)
If selected, acceptable AC input
voltage range will be within 170-
280VAC.
04
Power saving mode
enable/disable
Saving mode disable
(default)
If disabled, no matter connected load
is low or high, the on/off status of
inverter output will not be effected.
Saving mode enable
If enabled, the output of inverter will
be off when connected load is pretty
low or not detected.
05
Battery type
AGM
(default)
Flooded
User-Defined
If “User-Defined” is selected, battery
charge voltage and low DC cut-off
voltage can be set up in program 26,
27 and 29.