Power supply
ALSW2827
Input voltage
230V ~ +10% ÷ -15% - 50Hz
Maximum input current
600mA AC
Output
28V DC - I max. 2.7A
Further technical information available on installer manual
USB port
Preferiti
Desktop
Download
Computer
Disco locale (C :)
Raccolte
Documenti
Immagini
Musica
Video
ICO
ICO_MAP
IMG
MAP
MSG
RIP.PRG
RIP_PRV.PRG
CAL.PRG
log.txt
Ź
Computer
Ź
Disco locale D:
Ź7)76
ź
Nome file:
ź
Apri
Annulla
log.hex
Cerca file
Nome
Ultima modifica
7LSR
Dimensione
Organizza
Nuova cartella
Disco locale (D :)
USB port
The USB port allows to connect the control panel directly to a PC, for programming of the control panel and upgrade of its
fi
rmware. This connection supports only the standard Tecno
fi
re protocol from the Tecnoalarm and TECNOMONITOR software. The
USB interface can also be enabled by an access level 3 or 4 code, to allow access to the data Flash memory of the control panel
as a disk drive and customize the vocabulary using the Tecnoalarm software.
Serial port
The TTL port allows to connect a PC via the PROG32 or PROG USB interface, for programming of the control panel and upgrade
of its
fi
rmware. This port has longer transfer times compared to the USB port. The TTL port also allows to connect a serial printer.
LED
Signaling
D2
Green
Flashing = Run indication (proper running of control panel
fi
rmware)
D5
Red
On = USB cable connected
Port
Function
USB
PC connection for programming and
fi
rmware upgrade
SERIAL
Serial printer or programming interface connection
Supervision of jumpers
The control panel oversees the open or closed state of the jumpers to prevent that they are forgotten in the wrong position after
use, causing potential undesirable behaviors or malfunctioning of the control panel.
The control panel noti
fi
es the condition of anomaly, through a screen that indicates
System failure
and
KEY jumper inserted
.
The signaling remains visible until the relevant key jumper is correctly positioned.
N.B.
If the Automatic system failure acknowledgment function is not enabled, it is also necessary to perform a manual
acknowledgment to cancel the
System failure
noti
fi
cation.
System failure
System failure
16/02/2019
08:00:00
Access level 1
Control panel 1
Hotel Aurora
KEY JP inserted
16/02/2019 08:00:00
Содержание Tecnofire TF-A1-298-DE
Страница 2: ...TFA1 298 2 ...
Страница 4: ...TFA1 298 4 ...
Страница 10: ...TFA1 298 10 ...
Страница 14: ...TFA1 298 14 ...
Страница 28: ...TFA1 298 28 ...
Страница 32: ...TFA1 298 32 ...
Страница 40: ...TFA1 298 40 ...
Страница 46: ...TFA1 298 46 ...
Страница 55: ...TFA1 298 55 NOTES ...