![TECHTOP TD20 Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/techtop/td20-series/td20-series_product-manual_1070893009.webp)
TD20 Series VFD
Product Overview
-7-
Function
Specification
1. The VFD with plastic casing should be installed in metal
distribution cabinet, which conforms to IP20 and of which
the top conforms to IP3X.
2. Install device in pollution degree 2 environment
Cooling
Air-cooling
Braking unit
Embedded
EMI filter
Optional filter: meet the degree requirement of IEC61800-3
C2, IEC61800-3 C3
Safety
Meet the requirements of CE, UL and CUL
Overvoltage category
1PH&3PH 240V: Used in Canada only: "Transient surge
suppression shall be installed on the line side of this
equipment and shall be rated 240V (phase to ground),
240V (phase to phase), suitable for overvoltage category
III, and shall provide protection for a rated impulse
withstand voltage peak of 4kV" or equivalent.
3PH: Used in Canada only: "Transient surge suppression
shall be installed on the line side of this equipment and
shall be rated 480V (phase to ground), 480V (phase to
phase), suitable for overvoltage category III, and shall
provide protection for a rated impulse withstand voltage
peak of 6kV" or equivalent.
2.3 Nameplate
Figure 2-1 Nameplate
2.4 Type designation key
The type designation contains information on the VFD. The user can find the type designation on the
type designation label attached to the VFD or the simple nameplate.
E509291
IND. CONT. EQ
TD20-2R2G-4
2.2 kW/3 HP
AC 3PH 380V–480V 5.8A 50/60 Hz
AC 3PH 0V–Uinput 5.5A 0Hz–400Hz
Techtop Canada Inc.
TechtopCanada.com
S/N:
Made in China
Содержание TD20 Series