![TECHTOP TD20 Series Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/techtop/td20-series/td20-series_product-manual_1070893068.webp)
TD20 Series VFD
Function Parameters
-66-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
3: Neither
∧
/
∨
keys nor digital potentiometer
adjustments are valid
LED tens: frequency control selection
0: Only valid when P00.06=0 or P00.07=0
1: Valid for all frequency setting manner
2: Invalid for multi-step speed when multi-step speed
has the priority
LED hundreds: action selection during stopping
0: Setting is valid
1: Valid during running, cleared after stopping
2: Valid during running, cleared after receiving the stop
command
LED thousands:
∧
/
∨
keys and analog potentiometer
integral function
0: The Integral function is valid
1: The Integral function is invalid
P08.43
Integral ratio
of the keypad
potentiometer
0.01
–10.00s
0.10s
○
P08.44
UP/DOWN
terminals
control setting
0x00
–0x221
LED ones: frequency control selection
0: UP/DOWN terminals setting valid
1: UP/DOWN terminals setting valid
LED tens: frequency control selection
0: Only valid when P00.06=0 or P00.07=0
1: All frequency means are valid
2: When the multi-step are priority, it is invalid to the
multi-step
LED hundreds: action selection when stop
0: Setting valid
1: Valid in the running, clear after stop
2: Valid in the running, clear after receiving the stop
commands
0x000
○
P08.45
UP terminals
frequency
changing ratio
0.01
–50.00s
0.50 s
○
P08.46
DOWN
terminals
frequency
0.01
–50.00s
0.50 s
○