![TECHTOP TD20 Series Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/techtop/td20-series/td20-series_product-manual_1070893018.webp)
TD20 Series VFD
Installation Guide
-16-
supply. The default setting is NPN internal mode.
U-shaped contact
tag between
+24V and PW
U-shaped contact
tag between
COM and CME
Figure 3-8 U-shaped contact tag
If the signal is from NPN transistor, please set the U-shaped contact tag between +24V and PW as
below according to the used power supply.
S1
S2
COM
PW
+
24V
COM
+
24V
S1
S2
COM
PW
+
24V
COM
+
24V
+
24V
Figure 3-9 NPN modes
If the signal is from PNP transistor, please set the U-shaped contact tag as below according to the used
power supply.
S1
S2
COM
PW
+
24V
COM
+
24V
S1
S2
COM
PW
+
24V
COM
+
24V
Figure 3-10 PNP modes
3.3 Layout protection
3.3.1 Protecting the VFD and input power cable in short-circuit situations
Protect the VFD and input power cable in short circuit situations and against thermal overload.
Arrange the protection according to the following guide.