Page
42
sur
47
TRAÇABILITÉ CRÉATIVE
CREATIVE TRACEABILITY
www.technomark-marking.com
Modèle du 29/10/2015
TECHNOMARK
3 Allée Michaël FARADAY
Parc d’activités STELYTEC
42400 SAINT-CHAMOND (France)
Tel : +33 (0) 4 77 22 25 91
Fax : + 33 (0) 4 77 22 38 93
E-mail : [email protected]
8.4.
16
way
settings
Default 16 way settings is the following:
Illustration 28 : 16 way window
Number : the number of the input‐output
ES : type input or output
Function: function associated to the input‐output. Functions are available are not the same for the input or
output type.
o
Input functions :
None: no function associated.
Start: start the marking – works with impulsive mode.
Stop: stop the marking – works with impulsive mode.
Pause: pause the marking – works with impulsive mode.
Part presence: allow marking start if a detection system is connected on the input part
presence. Otherwise the marking start is forbidden.
Wait: waiting input to include a marking file (5.4.3 add a waiting input).
Reset serial: reset the serial numbers of the file – works with impulsive mode (5.3.1 Add a
serial number).
Serial increment: increase the file serial numbers – works with impulsive mode (5.3.1 Add a
serial number).