RUN 600 XTPRO: Service & Maintenance Manual - rev. 1.3
Page 2.9
pulled taut and eventually detaches the magnet when the distance becomes excessive. The
absence of the magnet causes the reed relay to commutate from closed to open, generating the
emergency signal. The safety switch requires cable RXIMQ-13S to be modified as follows:
RX-13USA: Emergency cable
CPU – Emergency button – Safety switch
CPU board
CN6
Signal
Color
Emergency
button
Safety switch
1 NC
contact
Black 2
-
- NC
contact
Yellow 1
2
2 Reference
Orange -
1
An upgrade kit is available (code 0WK247) for installing the safety switch on European
machines.
The other cables are unchanged. Therefore, for their description, refer to the details provided for the
220 Model.