Press ENTER (7, fig. 4.1) after having switched on the panel: the screen shows the machine main menu composed as
follows:
HIGH
High pasteurisation cycle,
with
heating
at
85°C
followed by cooling at 4°C
LOW
Low pasteurisation cycle,
with
heating
at
65°C,
maintenance for 30 minutes,
followed by quick cooling at
4°C
CUSTOM
Cycle
the
user
can
customise by selecting the
temperature from 60°C to
90°C. This cycle is required
as some ingredients are
sensitive
to
high
temperatures. The user can
select the different menus
entries using the left arrows
(pos. 6 and 8, fig. 4.1). The
wanted
entry
is
automatically selected when
highlighted (lit-up).
Using the left arrows (pos. 1
and
3,
fig.
4.1)
the
"Temperature"
in
the
CUSTOM cycle can be
varied (the Temperature in
the HIGH and LOW cycles is
fixed). The micro-processor
automatically defines the
Maintenance in temperature
time before quick cooling,
that is the same for all cycle
types.