Page 38 of 52
THIS MANUAL IS THE PROPERTY OF
TECHNOGEL SpA
–
ALL REPRODUCTIONS, EVEN PARTIAL, ARE FORBIDDEN
38
The display shows the wording
“
E00
+
RETE OFF
”
There was a black-out during the cycle:
this wording appears upon restart.
When the current is back, the machine
automatically starts in the same
conditions of when the black-out
occurred.
Press ENTER: the alarm wording
disappears.
The display shows the wording
“
E11 + PT100-S0
”
Faulty tank temperature sensor
The machine locks and cannot be
released.
Contact the Technical Assistance
The display shows the wording
“
E12 + PT100-S1
”
Faulty inlet glycol temperature sensor
The machine locks and cannot be
released.
Contact the Technical Assistance
The display shows the wording
“
E13 + PT100-S2
”
Faulty bottom outlet glycol temperature
sensor
The machine does not lock, only visual
alarm present. Contact the Technical
Assistance
The display shows the wording
“
E14 + PT100-S3
”
Faulty top outlet glycol temperature
sensor
The machine does not lock, only visual
alarm present. Contact the Technical
Assistance
The display shows the wording
“
E15 + TMAX R
”
Exceeding of limit time for heating
The machine does not lock, only visual
alarm present.
Check the stirrer speed in relation to
the density of the mix
Contact the technical assistance if the
alarm repeats
The display shows the wording
“
E16 + TMAX F
”
Exceeding of limit time for cooling
The machine does not lock, only visual
alarm present.
Check the stirrer speed in relation to
the density of the mix
Contact the technical assistance if the
alarm repeats
The display shows the wording
“
E21
”
Cooling cycle not regularly completed
due to: no power supply extension
Assess the possibility of repeating the
cycle
The display shows the wording
“
E22
”
Stop cycle not regularly completed due
to: no power supply extension
Assess the possibility of repeating the
cycle
The display shows the wording
“
E23
”
Preservation cycle not regularly
completed due to: no power supply
extension
Assess the possibility of repeating the
cycle
The display shows the wording
“
E09 + G MIN
”
The glycol level is too low
Contact the technical assistance
8 - ATTACHED DOCUMENTATION
8.1
LIST OF ATTACHED DOCUMENTS
-
List of equipment
-
EC Declaration of conformity (see Chap. 1)
-
Wiring diagram