23
The last row in the PROGRAMS menu is
DATA: press ENTER to access the DATA
menu. Below are the entries of this menu:
SAVE
The machine is fitted with USB port at the
bottom of the control panel for the connection of
an external memory (e.g. USB key 2.0
formatted FAT32) on which it is possible to
download the temperature and time registration
data of the program to be started.
Once the key is inserted, select SAVE using the
LEFT KEYS.
Select "Y" (YES) with the RIGHT ARROW: the
machine starts downloading data on the
external memory once out of the DATA menu
and after functioning start. The saved data is:
time, temperature and other mix cycle data with
a frequency of 2 minutes. The downloaded file
is called "
ci.par
" (txt file openable from
NOTEPAD or EXCEL).
Saving stops when STOP is pressed. The
selected work cycle stops.
This option is only active for machines fitted
with a printer.
Select PRINT using the LEFT KEYS.
Select "Y" (YES) with the RIGHT ARROW: the
machine prints its current process data on
paper (temperature and work times) during the
work cycle.
ALARM
REG
Select ALARM REG using the LEFT KEYS.
Press ENTER to access the ALARMS LOG that
displays the codes of the last 20 alarms
occurred during functioning. The most recent is
found top-left, and the least bottom-right.
The alarms coding ("E + 2 digit number") is
shown in table 7.1