32
The time program menu
In this menu a shift worker time program, up to 5 time programs (P1-P5), a rate time and the
date can be configured.
For every time program 3 windows with the possible allocation of a set value (
NV
) are availa-
ble. During the switch-on times the heating mode with the allocated set values applies for the
heating circuit. If no individual set values are assigned
RTN
(= room temperature in normal
operation) is used. Outside the time programs (lowering mode)
RTL
(= room temperature in
lowering mode) applies as set value. If no time program is set, then
RTL
is used as the set
value. RTN and RTL are adjustable in the basic control level. Every time program can be
assigned to any weekdays.
Shift worker time program SWP
(from version1.7)
:
With this it is possible to create several time programs with differing heating periods and to
specifically enable time windows simply by setting the parameters
SWP
.
SWP = --
All 5 time programs are used for the heating
SWP = 1
Currently only time program 1 is permitted for the heating
SWP = 15
Currently only the time programs 1 and 5 are permitted for the heating.
Adjustment range: SWP 15 to SWP 45
Application example
: For a combination of time program
TIMEP1
with
TIMEP5
(setting:
SWP 15
)
TIMEP1
is the time program during shift work and
TIMEP5
the program for the
weekend.
Shift worker time
program
Time program 1 up to
Time program 5
Rate time
Weekday
on Weekday
off
Time
window
Date